l Compact size, high reliability
l High reliability
l Built-in EMI filter
l Top brand components for key parts
l Protections: overload/ short circuit
l F602 111 x 78 x 36(mm)
AC input voltage range: 170~264VAC (210~370VDC)
Input frequency: 47~63Hz
Inrush current: cold start, 40A/230V
Input leakage current: ?0.7mA/ 230VAC
Line regulation (full load): ??0.5%
Load regulationV1: ??1%, V2,V3: ??3% (with regulators); ??10% (without)
Output voltage adjust range: single output:?10%, multi-output: V1:?5%
Output overload protection: 105~150%, hiccup mode, auto recovery
Withstand voltage:
I/P -O/P: 1.5KVAC/1min
I/P -F/G: 1.5KVAC/1min
O/P-F/G: 0.5KVAC/1min
Rise time: 50ms@full load (typical)
Hold up time: 20ms@full load (typical)
Operating temperature: -20?~+50?
Safety standards: design meet GB4943, UL60950, EN60950
EMC standards: design meet GB9254, EN55022 classA EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
Cooling method: convection